Heat loss thermal insulation there are three general types of ground floor construction.
Insulated solid floor construction.
If the floor is a ground floor provide resistance to.
Insulating solid ground floors below ground bearing slab sand blinding and hardcore radon barrier dpm quinn therm qf pir insulation boards quinn lite pac eps insulation boards quinn therm edge insulation concrete slab on separating layer timber flooring on polyethylene slip sheet sand blinding and hardware radon barrier dpm quinn therm.
The panels provide a continuous energy efficient surface.
Read more about changes to thermal elements in the external walls section.
Solid floor insulation cost.
The building regulations backstop target u value for ground floors is 0 25w m2k which should be easily achievable with 75mm or 100mm thick rigid insulation boards laid over the surface.
Insulation under ground floor slabs is a good way of meeting the increased requirements of parts l f of the building regulations.
For solid concrete floors make sure that if they need to be replaced your builder puts in insulation you have to insulate a floor when it is replaced in order to comply with building regulations.
Renovation of more than 25 per cent of a solid or suspended floor involving the replacement of screed or a timber floor deck would have to meet the standards required by the building regulations approved documents.
In a solid or ground bearing because it is continuously supported by the ground across its whole area concrete floor the choice of insulation position relative to the concrete slab is commonly linked to the building s heating system.
Insulation is laid on the concrete and covered with a screed.
A typical way of constructing a solid floor would be to provide a base of hardcore with sand blinding with a layer of concrete over that.
This eliminates thermal bridging which is the energy lost through wall studs.
Insulating a solid floor.
Polyurethane pur is a more effective insulator than expanded polystyrene eps meaning a thinner board can be laid to achieve the same results.
Most modern homes have a solid floor for example.
There will be a damp proof membrane under the insulation and possibly a second membrane on top depending on the type of screed.
These can be fitted with new rigid concrete solid flooring or fixed plasterboard that should help fill any cracks or gaps formed over time and improve the overlay s insulating properties.
Insulated foam sheets are also used as an insulated sheathing underlayment for exterior siding.
Most newer properties will already have solid floor bases constructed directly below a room especially on the ground floor.